Contact Us
Biomap Limited
Britannia House11 Glenthorne Road
Hammersmith
London
W6 0LH
Tel : +44 (0) 208 748 1039
Fax : +44 (0) 207 904 2015
Email: info@biomap.co.uk
TEMPERATURE DATA LOGGERS
- Escort Intelligent MINI
- Escort IminiPlus
- Escort IminiPlus PDF
- Escort IminiPlus Dry Ice
SOFTWARE
- Console Pro
- Web Track
STRIP CHART RECORDERS
- Bioconservacion
TEMPERATURE INDICATOR LABELS
- ColdMark
- WarmMark
- 3M Freeze Watch
- 3M MonitorMark
ELECTRONIC TEMPERATURE INDICATORS
- TempMark8
WIRELESS CONTINUOUS MONITORING SYSTEM
- Hanwell Wireless Monitoring System
- Base Station Receivers
- 4000 Series Transmitters
- 5000 Series Transmitters
- Alarm Options
5000 Series Transmitters – Low temperature, CO2 and Differential Pressure
The rl5000 range is a new series of Hanwell radio telemetry transmitters, designed for use with the Radiolog 8 environmental monitoring system. The units are in IP65-rated cases and are suitable for use in tough environments.
Each rl5000 has two inputs for probes, the combination of which can be custom-defined. Supported temperature probe types include: thermistors and PT100s. The rl5000 also supports humidity probes and linear inputs. Probes are supplied separately.
The transmitter ID, transmission speed and calibration data is programmed into its on-board memory using Radiolog 8, a software package which automatically recognises the type of unit connected to the PC via the USB lead.
The custom-designed LCD indicates current readings of two channels (based on the on-board calibration data), battery life and alarm conditions.
The transmitter is typically powered by a 7.5V 2700mAh battery pack, which can be fitted by the user. Larger battery packs are available as is option of permanent power. The battery life will be dependant on the number of inputs and the transmission speed. An indicator on the LCD will warn when the battery is low, and the transmitter maintains a record of when the battery has been changed.
The rl5000 range has been designed to comply with the RoHS and WEEE EU directives, and carries the CE mark.
Low Temperature – rl5002

Each rl5002 has two inputs for probes, the combination of which can be custom-defined. Supported temperature probe types include: thermistors, PT100s and thermocouples. The rl5000 also supports humidity probes and linear inputs. Probes are supplied separately.
Specifically, the rl5002 ahs probe options to record down to -200C for LN2 environments.
The transmitter ID, transmission speed and calibration data is programmed into its on-board memory using Radiolog 8, a software package which automatically recognises the type of unit connected to the PC via the USB lead.
The custom-designed LCD indicates current readings of two channels (based on the onboard calibration data), battery life and alarm conditions.
Benefits
• Provides ongoing record of temperature
• Unrivalled radio technology
• Can be easily integrated into an existing Hanwell system
Typical Applications
• Warehouse
• Pharmaceutical
• Laboratory
• Building monitoring & control
• Event logging
• Temporary
Differential Pressure – rl5405

The rl5405 DP radiotelemetry transmitter, designed for use with the Radiolog 8 environmental monitoring system. The units are in IP65-rated cases and are suitable for use in tough environments.
Utilising an integral temperature compensated pressure sensor the rl5405 differential pressure transmitter delivers exceptional performance. The sensor utilises a silicon, micro machined, stress concentration enhanced structure to provide a very linear output to the measured pressure. The ports are designed with matched dead volumes. This series is intended for use with non-corrosive, nonionic working fluids such as clean dry air, dry gases and the like.
The media wetted materials are the silicon diaphragm, glass filled nylon, RTV and alumina ceramic. The transmitter ID, transmission speed and calibration data is programmed into its onboard memory using Radiolog 8, a software package which automatically recognises the type of unit connected to the PC via the USB lead.
Specifications
• Instrument operating range
o -20 to +60
• Pressure sensor operating range (Minature Silicon Sensor) +/-50 Pa
• Accuracy +/- 0.5
• Resolution 0.1 Pa
Benefits
• Provides ongoing record of differential pressure
• Unrivalled radio technology
• Wireless range can reach up to 3km on open ground
• Can be easily integrated into an existing Hanwell system
Typical Applications
• Measuring positive, negative and differential pressures
• Pharmaceutical industry
• Clean rooms
• Laboratories
CO2, Temperature & Humidity - rl5406 ClimaBox3

In today’s energy conscious world everybody is looking for ways to cut down on energy use. An easy way to see a reduction in energy is to control your ventilation by demand, by measuring the amount of CO2 breathed into the air, ventilation systems can be controlled to deliver the exact amount of ventilation required at the right time.
By using a ClimaBox accurate reliable readings can be obtained. With the ClimaBox there is no need to hard wire through the building as the ClimaBox communicates wirelessly to either a Hanwell control system or directly to the BMS system.
Specifications
• Instrument operating range
o -20 to +70
• Sensor operating range
o CO2 (E+E Dual Source Infra Red System) 0….4000ppm
o Temperature (Precision Thermistor) -10 to +60
o Humidity (Capacitive Polymer) 0 - 100% RH Non-condensing
• Accuracy
o CO2 +/-50ppm or ± 3% of measured value
o Temperature +/- 0.1
o Humidity +/- 2%
• Resolution
o Temperature 0.1
o Humidity 0.1% RH
Benefits
• Can be easily integrated into an existing Hanwell system
• Provides ongoing record of temperature, humidity and CO2
• Unrivalled radio technology
• Full data history for comprehensive analysis
Typical Applications
• Ventilation studies
• Environmental monitoring
• Building monitoring & control
• Occupancy studies
The rl5000 range is a new series of Hanwell radio telemetry transmitters, designed for use with the Radiolog 8 environmental monitoring system. The units are in IP65-rated cases and are suitable for use in tough environments.
Each rl5000 has two inputs for probes, the combination of which can be custom-defined. Supported temperature probe types include: thermistors and PT100s. The rl5000 also supports humidity probes and linear inputs. Probes are supplied separately.
The transmitter ID, transmission speed and calibration data is programmed into its on-board memory using Radiolog 8, a software package which automatically recognises the type of unit connected to the PC via the USB lead.
The custom-designed LCD indicates current readings of two channels (based on the on-board calibration data), battery life and alarm conditions.
The transmitter is typically powered by a 7.5V 2700mAh battery pack, which can be fitted by the user. Larger battery packs are available as is option of permanent power. The battery life will be dependant on the number of inputs and the transmission speed. An indicator on the LCD will warn when the battery is low, and the transmitter maintains a record of when the battery has been changed.
The rl5000 range has been designed to comply with the RoHS and WEEE EU directives, and carries the CE mark.
Low Temperature – rl5002

Each rl5002 has two inputs for probes, the combination of which can be custom-defined. Supported temperature probe types include: thermistors, PT100s and thermocouples. The rl5000 also supports humidity probes and linear inputs. Probes are supplied separately.
Specifically, the rl5002 ahs probe options to record down to -200C for LN2 environments.
The transmitter ID, transmission speed and calibration data is programmed into its on-board memory using Radiolog 8, a software package which automatically recognises the type of unit connected to the PC via the USB lead.
The custom-designed LCD indicates current readings of two channels (based on the onboard calibration data), battery life and alarm conditions.
Benefits
• Provides ongoing record of temperature
• Unrivalled radio technology
• Can be easily integrated into an existing Hanwell system
Typical Applications
• Warehouse
• Pharmaceutical
• Laboratory
• Building monitoring & control
• Event logging
• Temporary
Product Code | Series | Channels |
RL-5002-434.075 | RL5000 | Dual |
Differential Pressure – rl5405

The rl5405 DP radiotelemetry transmitter, designed for use with the Radiolog 8 environmental monitoring system. The units are in IP65-rated cases and are suitable for use in tough environments.
Utilising an integral temperature compensated pressure sensor the rl5405 differential pressure transmitter delivers exceptional performance. The sensor utilises a silicon, micro machined, stress concentration enhanced structure to provide a very linear output to the measured pressure. The ports are designed with matched dead volumes. This series is intended for use with non-corrosive, nonionic working fluids such as clean dry air, dry gases and the like.
The media wetted materials are the silicon diaphragm, glass filled nylon, RTV and alumina ceramic. The transmitter ID, transmission speed and calibration data is programmed into its onboard memory using Radiolog 8, a software package which automatically recognises the type of unit connected to the PC via the USB lead.
Specifications
• Instrument operating range
o -20 to +60
• Pressure sensor operating range (Minature Silicon Sensor) +/-50 Pa
• Accuracy +/- 0.5
• Resolution 0.1 Pa
Benefits
• Provides ongoing record of differential pressure
• Unrivalled radio technology
• Wireless range can reach up to 3km on open ground
• Can be easily integrated into an existing Hanwell system
Typical Applications
• Measuring positive, negative and differential pressures
• Pharmaceutical industry
• Clean rooms
• Laboratories
Product Code | Series | Channels |
RL-5405-434.075 | RL5000 | Dual |
CO2, Temperature & Humidity - rl5406 ClimaBox3

In today’s energy conscious world everybody is looking for ways to cut down on energy use. An easy way to see a reduction in energy is to control your ventilation by demand, by measuring the amount of CO2 breathed into the air, ventilation systems can be controlled to deliver the exact amount of ventilation required at the right time.
By using a ClimaBox accurate reliable readings can be obtained. With the ClimaBox there is no need to hard wire through the building as the ClimaBox communicates wirelessly to either a Hanwell control system or directly to the BMS system.
Specifications
• Instrument operating range
o -20 to +70
• Sensor operating range
o CO2 (E+E Dual Source Infra Red System) 0….4000ppm
o Temperature (Precision Thermistor) -10 to +60
o Humidity (Capacitive Polymer) 0 - 100% RH Non-condensing
• Accuracy
o CO2 +/-50ppm or ± 3% of measured value
o Temperature +/- 0.1
o Humidity +/- 2%
• Resolution
o Temperature 0.1
o Humidity 0.1% RH
Benefits
• Can be easily integrated into an existing Hanwell system
• Provides ongoing record of temperature, humidity and CO2
• Unrivalled radio technology
• Full data history for comprehensive analysis
Typical Applications
• Ventilation studies
• Environmental monitoring
• Building monitoring & control
• Occupancy studies
Product Code | Series | Channels |
RL-5406-434.075 | ClimaBox | Dual |
